Description of Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
The short-tube Rotameter is used for measurement of flow rates of liquids and gases. Its special application is in troubled, opaque or aggressive mediums. The instrument is mounted in a vertical pipeline with flow direction upwards.
Inside the special shaped conicmetal tube, a float is guided concentrically. The position of this float is magnetically transmitted to the indicator. The indicators are exchangeable without influence on the accuracy.
FEATURES of Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
• Different process connections like flanges according to EN and ASME
• All wetted parts in stainless steel or PTFE
• Maximum flow 0.025 - 130 m³/h water resp. 0.75 - 1400 m³/h air (20 °C/ 1.013 bar abs)
• Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2(qG=50 %)
• Float damping to avoid float bouncing with gas applications
• Optional heat tracing (with steam or fluid heat carrier)
• Indicator in stainless steel, aluminium, protection class IP66/67
• Local indicator without additional power supply
• Microprocessor controlled transmitter with 24 V, 115 V or 230 V power supply
• Intrinsically safe version (Ex-i): ATEX, IECEx, FM (US/C),NEPSI, PESO, EAC, INMETRO
• Flame proof version (Ex-d): ATEX, IECEx, NEPSI, PESO,KOSHA, EAC, TS
• Dust explosion proof: ATEX, IECEx, NEPSI, PESO, KOSHA
• Ex for non- electrical RAMC: ATEX, EAC
• FMEDA report available for SIL application
• Limit switches, also available as “Fail Safe” version
Characteristics of Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
• Flow indication (totalize, actual, percent)
• Indication of different volume- and mass flow units
• Second (manual) calibration storing
• Patented float blocking indication function
• Signal output damping
• Error message indication
• Temperature measurement in the electronic transmitter
• HART5/7-Communication
• Profibus PA-Communication
Specification of Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
For Pipe Sizes |
DN 15 to DN 25 (1/4” – 1“) |
Process Connections |
Flange, threaded |
Measuring Range |
Water 20 °C: 2,5 l/h to 130 m³/h |
Wetted Parts Material |
1.4404 (AISI 316L), PTFE-lining Hastelloy, |
Process Temperature |
-200 °C to + 370 °C |
Process Pressure |
100 bar, higher pressures on request |
Ambient Temperature |
-40 °C to 100 °C |
Accuracy acc. VDE/VDI 3513-2(qG =50%) |
1,6 % |
Ex-approvals |
ATEX, FM(US,C), NEPSI |
Signal Outputs |
Analog 0-20mA / 4-20mA, pulse output |
Communication |
HART, Profibus PA |
Power Supply |
24 V DC 2-wire, 24 V DC 3-wire, 115 V AC 4-wire, 230 V AC 4-wire |
Degree of Protection |
IP66/IP67 |
Suitable for Applications acc. IEC 61508 and Machinery Directive ISO 13849 |
Yes |
Additional Features |
Patented float blockage detection system |
Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
Model | Suffix code | Description | Restrictions | ||||||
RAMC01 | Size DN 15 (½ inch) | for D4, D6, A1, A2, A3, T4, R4, T6, G6 | |||||||
RAMC23 | Size DN 20 (¾ inch) | for D4, D6, A1, A2, A3, T4, R4, T6, G6 | |||||||
RAMC02 | Size DN 25 (1 inch) | for D4, D6, A1, A2, A3, S2, S4, S5, T4,R4, T6, G6 | |||||||
RAMC03 | Size DN 32 (1¼ inch) | for D4, D6, A1, A2, A3, S4, T6, G6 | |||||||
RAMC04 | Size DN 40 (1½ inch) | for D4, D6, A1, A2, A3, S4, S5, T6, G6 | |||||||
RAMC05 | Size DN 50 (2 inch) | for D4, D5, D6, A1, A2, A3, S2, S4,T4, R4 | |||||||
RAMC06 | Size DN 65 (2½ inch) | for D4, D5, A1, A2, A3, S2, S4, T4, R4,T6, G6 | |||||||
RAMC08 | Size DN 80 (3 inch) | for D4, D5, A1, A2, A3, S2, S4 | |||||||
RAMC09 | 3½ inch | for A1, A2 | |||||||
RAMC10 | Size DN 100 (4 inch) | for D2, D4, A1, A2, S4, S4 | |||||||
RAMC12 | Size DN 125 (5 inch) | for D2, A1, A2, S2 | |||||||
RAMC15 | Size DN 150 (6 inch) | for D2, A1, A2 | |||||||
RAMCNN | Without measuring tube | ||||||||
|
Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
Yokogawa RAMC08-D4SS-74V8-T90NNN/IE1 RAMC08 Flowmeters RAMC08 Rotameters Germany Origin
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
We mainly supply Yokogawa, Emerson, Rosemount, Fisher, Honeywell, Siemens, ABB, FLUKE, Endress+Hauser, Schneider Electric, Pepperl+Fuchs, MTL, Rockwell(Allen Bradley), Hirschmann, Eaton, Moeller, FUJI, Omron, Yaskawa, Norgren, CHINT, Hach, Weidmuller, Phoenix, SMC, Testo, ASCO, Parker, Mitsubishi, Festo, GE, CISCO, Auma, IFM, GM, Turck, Bently Nevada, MOXA, Krohne, Foxboro and so on.
Why choose us?
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
Packaging:
Imported with original packaging or standard export packing.Customize design is acceptable.
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)